陕西快乐十分最大遗漏数据
上海玉研科學儀器有限公司

電話:021-35183767
???021-54377179

傳真:021-35183767-8008

QQ:2113136797

地址:上海市閔行區興梅路485號 XingMei Rd 485,Shanghai,China

當前位置:首頁 > 疼痛與炎癥研究 > 雙足平衡測痛儀
疼痛與炎癥研究

雙足平衡測痛儀

時間:2016-09-17來源:本站作者:玉研儀器

詳細介紹

雙足平衡測痛儀(雙足平衡測試,Incapacitance Analgesia TestIncapacitance Meter Tester Mice, Rats and Birds測試評估大鼠或小鼠后肢的痛覺和發炎,測量精準,更多詳情敬請來電咨詢)


型號:600MR

 

雙足平衡法測痛儀用于對大鼠或小鼠后肢的痛覺和發炎測試評估,克服了其它測試方式可能引起的動物緊張或主觀性問題,該技術采用雙通道重量平均法,可以同時對一只動物進行控制和測試,可選購大鼠或小鼠兩種型號。

 

雙足平衡測試法(Incapacitance Analgesia Meter)可以自動并且是可重復的評估止痛效果。它可測量體重在小動物后肢分配情況,每個肢體對感應器施加的力量,在選定的時間周期內的平均值,可以表現受試對象從一邊到另一邊的抬起足部,因此可以提供量化的體重在后肢的平衡分配。

 

Incapacitance Test Meter is used for test assessment of pain and or inflammation of the hind limbs on mice and rats. It overcomes the drawbacks of other methods that might cause unnececessary stress or subjectivity on the animal. The technique known as dynamic weight bearing enables the test on both limbs allowing a clean stress free correlation to the paw pressure test. Control and testing can be done on the same animal at the same time.


Animals are placed in the supplied rodent restrainers. Hind limbs rest on the two weight averaging platform pads. As the animal shifts their weight from each pad, the unit records the average weight in grams over a selectable test period of 5 to 999 seconds. Alphanumeric readout displays the weight of both limbs and testing start and stop features. These features are controlled on the front panel: Start, stop, reset.

 

雙足平衡法測痛儀主要特點: 

 

? Mice, Rats, and Birds

? Precise programmable digital control 

? Reaction is detected automatically 

? Manual override of all timer functions 

? Alphanumeric readout 

? All Functions and parameters entered via key-pad 

? Footswitch - RS232

? Software - USB (optional)

 

部分參考文獻:

Evaluation of liposome-encapsulated butorphanol tartrate for alleviation of experimentally induced arthritic pain in green-cheeked conures (Pyrrhura molinae)

JR Paul-Murphy, LA Krugner-Higby… - American journal of …, 2009 - Am Vet Med Assoc

... f. Paralube, Fougera, Melville, NY. g. IITC model 600 incapacitance meterIITC Life
Science, Woodland, Calif. h. Canon Optura 40, Canon USA Inc, Lake Success, NY. i.
Windows Movie Maker, version 2.1, Microsoft Corp, Redmond, Wash. ...

 

[HTML] Hyperalgesia, synovitis and multiple biomarkers of inflammation are suppressed by interleukin 1 inhibition in a novel animal model of gouty arthritis

R Torres, L MacDonald, SD Croll, J Reinhardt… - Annals of the …, 2009 - ard.bmj.com

... The results are presented as the percentage change from the baseline readings. To test
willingness to bear weight on injected ankles, the weightbearing test was performed using an
Incapacitance meter (model 600IITC Life Sciences, Woodland Hills, California, USA). ...

 

Analgesic effects of carprofen and liposome-encapsulated butorphanol tartrate in Hispaniolan parrots (Amazona ventralis) with experimentally induced arthritis

JR Paul-Murphy, KK Sladky… - American journal of …, 2009 - Am Vet Med Assoc

... d. Rimadyl injectable, 50 mg/mL, Pfizer Animal Health, Exton, Pa. e. IITC model 600 incapacitance meterIITC Life Science, Woodland, Calif. f. Canon Optura 40, Canon USA Inc, Lake Success, NY. g. Saint Louis Zoo Endocrinology Lab, Saint Louis Zoo, St Louis, Mo. ...

 

Analgesic effects of intramuscular administration of meloxicam in Hispaniolan parrots (Amazona ventralis) with experimentally induced arthritis

GA Cole, J Paul-Murphy… - American journal of …, 2009 - Am Vet Med Assoc

... d. 0.9% sodium chloride injection, USP, Hospira, Lake Forest, Ill. e. IITC Incapacitance Meter, model 600IITC Life Science, Woodland Hills, Calif. f. 24A-D Series parallel Shaft DC Gearmoter, model 0194, serial No. 0194JTE0015, Bodine Electric Co, Chicago, Ill. ...

 

[PDF] Kinematic and dynamic gait compensations resulting from knee instability in a rat model of osteoarthritis

KD Allen, BA Mata, MA Gabr, JL Huebner… - Arthritis Res …, 2012 - biomedcentral.com

... weight distribution was measured on an incapacitance meter (IITC, Inc., Woodland Hills, CA, USA), a behavioral analysis assay that measures weight bearing on the hindlimbs while the animal is in an induced rear- ing posture [10]. In brief, an incapacitance meter con- sists of ...

 

Single intrathecal administration of the transcription factor decoy AYX1 prevents acute and chronic pain after incisional, inflammatory, or neuropathic injury

J Mamet, M Klukinov, TL Yaksh, SA Malkmus… - PAIN?, 2014 - Elsevier

... In the SNI and the knee surgery models, incapacitance was measured as the difference in static weight bearing between the ipsilateral versus contralateral hind paw relative to the injury using an incapacitance meter (model 600IITC Life Science, Woodland Hills, CA). ...

 

[PDF] Efficacy of an equine joint supplement, and the synergistic effect of its active ingredients (chelated trace minerals and natural eggshell membrane), as

KJ Wedekind, A Josie, J Zhao - 2015 - dovepress.com

... A Hamilton PB 600-1 repeating dispenser (model 750; Hamilton Company, Reno, NV, USA) with a 700 series luer tip microliter syringe was used for precise injection ... An incapacitance tester (IITC Life Science, Woodland Hills, CA, USA) was used to measure weight distribution. ...

 

[HTML] Behavioral, medical imaging and histopathological features of a new rat model of bone cancer pain

L Doré-Savard, V Otis, K Belleville, M Lemire… - PLoS One, 2010 - dx.plos.org

... Static weight bearing was measured using the Incapacitance Meter (IITC Life Science, Woodland Hills, CA, USA). ... The results obtained with the incapacitance meter were used as a control for a second ... A 600-μl bolus of contrast agent (Gd-DPTA, Magnevist, Berlex) was injected ...

 


 

    您想了解更多詳細資料嗎?

    請與我們聯系:

    TEL021-35183767021-54377179

         18502129044

    QQ3250431383

    微信:yuyanbio

    Mailyuyanbio@126.com

    歡迎您的咨詢!


qq在線客服
陕西快乐十分最大遗漏数据